2024年9月27日发(作者:运动木地板价格)

Installation Guide

安装说明

Smart Seat

清舒宝智能便盖

C3-130

K-4107T-0

K-4107T-XP-0

科勒(中国)投资有限公司

中国上海市静安区江场三路158号 邮编:200436

制造商:上海科勒电子科技有限公司

中国上海市宝山区丰翔路1955号 邮编:200444

English page 2-8

中 文 页 码

9-14

1194357-T01-L

220V~, 50Hz, 10A

on the product surface. Please ensure sufficient ventilation in your

surroundings to prevent possible damage to electronic components.

1194357-T01-L2Kohler Co.

Make sure the seat is positioned correctly so that it can be connected to

the thread of the inlet pipe. Otherwise, the inlet pipe thread may wear off

and lead to water leakage.

Min water pressure 0.07MPa (dynamic pressure),

Max water pressure 0.74MPa.

Do not use attachments not recommended by Kohler Co. such as

T-valve etc.

Unplug the seat and drain it, if the seat is not being used for an

extended period of time.

When install the product in the room, a stop valve shall be installed in

a close proximity. For emergency circumstances, the water inlet valve

shall be stopped without using any tools; otherwise unexpected failure

may cause the loss to the customer.

Kohler Co.31194357-T01-L

toilet roughing-in requirements and installation tips

2

3

1

5

4

ce between installation holes: 136 - 210mm.

ce between installation holes and tank front rim:>20mm.

ce between installation holes and bowl inner rim: <70mm.

ce between installation holes and tank top rim: 460 - 490mm.

inner diameter: 370 - 390mm.

distance between the seat and the plug should be maximum 1 meter.

l an Electrical Outlet

WARNING: Risk of electric shock, fire, or personal injury.

This product must be grounded. Connect only to a

dedicated 220V~, 50Hz, 10A circuit protected by Ground-Fault

Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker

(ELCB).

It is recommended to use water-resistant socket. Do not use an

extension cord with the product.

NOTE: Follow local codes when determining the electrical outlet location.

Route the electrical and install to a 220V~, 50Hz, 10A GFCI- or ELCB-

protected receptacle.

ation

Turn off the water supply to the toilet.

Flush the toilet to relieve any pressure from the water supply hoses.

Position a container under the fill valve to catch any excess water.

Disconnect the water supply hose from the toilet fill valve.

Remove the existing toilet seat.

1194357-T01-L4Kohler Co.

Mounting Plate

Mounting Plate

Nut

l the Mounting Plate

NOTE: Select the appropriate mounting plate according to the instruction for

mounting distance on the mounting plate.

Place the mounting plate in the mounting hole above the toilet.

Screws should be inserted respectively into the washers.

NOTE: Some toilets come with threaded inserts pre-installed in the mounting

holes. For toilets with threaded inserts, the nut is not required.

For Toilets with Threaded Inserts:

Insert a bolt through the mounting plate and position the washers so they

rest in the grooves of the mounting plates. Please pay attention to washer

direction.

Loosely thread the bolts into the inserts. Do not overtighten for further

adjustment.

For All Other Installations:

Position the mounting plate over the toilet mounting holes.

Slide a washer onto each of the bolts. Please pay attention to washer

direction.

Insert a bolt through the mounting plate and the toilet mounting holes.

Position the washers so they rest in the grooves of the mounting plate.

Thread a nut onto each of the bolts. Handtighten the nut.

Kohler Co.51194357-T01-L

Mounting Plate

l the Seat

Align the slot on the mounting plate with the groove located below the toilet

seat, slide the seat onto the mounting plate until you feel it snaps into place.

NOTE: The mounting plate may need to be adjusted to properly align with the

seat.

For Toilets with Threaded Inserts:

To adjust the seat position, remove the seat and reposition the mounting

plate as needed.

Once the seat is positioned as desired, remove the seat and securely tighten

down the mounting plate.

Reinstall the seat.

For All Other Installations:

No need to remove the seat for seat position adjustment. Adjust the position

seat and mounting plate only by loosening nuts and tighten nuts when they

are adjusted to properly align with the seat.

1194357-T01-L6Kohler Co.

T-Valve

Inlet Hose

Supply Stop

Hose

t the Water Supply

IMPORTANT! Risk of product damage. Take care to face right in position to

the inlet pipe thread and seat thread. Take care not to crossthread or overtighten

connections. Hand tighten plus one-quarter turn is sufficient for tightening.

IMPORTANT! Risk of product damage. Use care not to scratch the product

surfaces.

Connect the T-valve directly to the toilet fill valve.

NOTE! For those newly installed plumbing pipes, (before the inlet hose is

connected to the T-valve,) must flush for several seconds to clean the inner

side of the pipe in order to remove the dirt and debris, etc.

Connect the T-valve to the toilet seat with the supplied hose.

NOTE:Please use new hose enclosed with tools. Please do not reuse the

old hose.

Connect T-valve to water supply system (valve shall be purchased by

customer).

Turn on the water supply.

NOTE:Flush the water supply pipes thoroughly to remove debris. The

product is designed for tap water. Make sure not to use industrial water/grey

water/black water/sea water for the water supply.

Check all connections for leaks and make any adjustments asneeded.

Kohler Co.71194357-T01-L

1

lation Checkout

Ensure if water inlet valve is OPEN.

Wrap the toilet seat with plastic wrap t o prevent water from spraying

from the toilet during testing.

Toilet makes one short beep once it is plugged in. The nozzle

stretches out and draws back once. Backlight on the side keyboard

lights up and the night light flashes. All the actions last until the

initialization process completes.

Attach the clips evenly along the hose and power cord.

The seat is activated by skin-to-seat contact. Unless otherwise

stated, the seat must be occupied to activate the functions. To

activate the seat controls for testing purposes, when facing the toilet,

place your hand or a damp wash cloth on the right side of the seat

approximately 1/3 from the front of the seat (sensor area).

Proceed to the “Operation” section of the Homeowners Guide to test

the various seat functions.

1194357-T01-L8Kohler Co.

谢谢您选择科勒公司

我们感谢您对科勒质量的信任。在您开始安装前,请您花几分钟时间阅读

这本手册。如果您在安装或性能方面遇到任何问题,务必请您与我们联

系。再次感谢您选择科勒公司。

工具和材料

可调节扳手一字螺丝刀

安装之前

警告:触电,火灾或人身伤害的危险。本产品必须接地良好。

只能连接到专用的

220V~, 50Hz, 10A的带接地故障断路器或

接地漏电保护器的电路中。

警告:触电或产品损伤的危险。不要把产品浸没在水中。

重要!产品损伤的危险。在所有其他安装步骤结束之前不要插电源线插头。

重要!产品损伤的危险。不要把产品安装在水可能溅到的地方。

重要!产品损伤的危险。不要把产品安装在过分潮湿的地方,在这种地方,

水汽可能凝聚在产品表面。请始终保持使用环境有足够的通风,以防止电子

组件的损坏。

重要!产品损坏或财产损失的危险。硬推、硬拉水管接头可能造成水渗漏。

重要!产品损坏的危险。不要在喷嘴上施加过大的力,否则产品可能损坏。

重要!产品损坏的危险。

连接本产品进水管时要小心对正螺纹,否则会损坏

产品进水口螺纹,造成漏水。

遵守所有当地的管道和建筑标准。

这本说明中所有的信息基于最新公开的产品信息。科勒公司保留在

任何时间不通知的情况下做改变的权利。

不要使用延长电线连接产品。

最小进水压力0.07MPa(动压), 最大进水压力0.74MPa。

请不要使用科勒不推荐的附件,如三通等。

只能连接到自来水的水源。

如果产品长时间不用,请拔下插头并排干本机里的水。

在安装本产品的同一房间中,需要在触手可及的位置安装一个止水阀,

用于紧急情况下,无需借助工具即可切断本产品的进水水路;否则本

产品的意外故障可能会导致用户损失。

Kohler Co.91194357-T01-L

1.适配座便盖尺寸要求及安装小贴示

2

3

1

5

4

1. 安装孔的间距:136-210mm

2. 安装孔与水箱的距离:>20mm

3. 安装孔与座便器内圈的距离:<70mm

4.安装孔到座便器顶端的距离:460-490mm

5. 座便器内径尺寸:370-390mm

6.安装前请在座便器

左侧约 1米范围内预留

电源插座

2.安装电路出口

警告:触电,火灾或人身伤害的危险。本产品必

须接地良好。只能连接到专用的

220V~, 50Hz, 10A的带接地故障断路器或接地

漏电保护器的电路中。

建议使用防水型插座,不要使用延长电线连接产品。

注意:在决定电路出口位置时,要按照当地的标准。

连接到220V~, 50Hz, 10A并带有接地故障断路器或接地漏电保护器保

护的电路中。

3.准备

关闭座便器的供水系统。

冲洗座便器,释放来自供水管的压力。

在进水阀下方放置一个容器装多余的水。

断开座便器进水阀与供水管的连接。

移除现有的座圈。

1194357-T01-L10Kohler Co.

安装板

安装板

螺母

4.安装安装板

注意:按照安装板上安装距离提示,选择合适的安装板。

在座便器安装孔上方放置安装板。

把螺钉分别插入垫圈内。

注意:一些座便器的底板孔内已经有螺纹,这种座便器不需要螺母。

对有螺纹孔的座便器:

把螺钉插入安装板和座便器安装孔内,移动垫圈,使之卡在安装板的

凹槽内,注意垫片方向:垫片近孔折弯处向下。

顺着螺纹轻轻地拧紧螺丝,不要拧得过紧,以便调整。

对其他座便器:

在座便器安装孔上方放置安装板。

把每个螺丝分别插入垫圈内,注意垫片方向:垫片近孔折弯处向下。

把螺丝插入安装板和座便器的安装孔内。

移动垫圈,使之置于安装板的凹槽内。

在每个螺丝上拧上螺母,用手拧紧螺母。

Kohler Co.111194357-T01-L

安装板

5.安装座便盖

对正座便盖底部和安装板之间的卡槽,把座便盖在座便器座圈面上向

水箱方向移动,当听到咔嚓声说明安装完成。

注意:安装板可能需要调节来完全地对准座便器相对位置。

对有螺纹孔的座便器:

要调节座便盖位置,如有必要可以移除座便盖,重新调节安装板的位

置。

一旦座便盖位置确定,移除座便盖,牢固的拧紧安装板。

重新安装座便盖。

对其他座便器:

要调节座便盖的位置,不需移除座便盖,只需拧紧螺母,即可摆动调

节座便盖及安装板的位置,当位置适当,直接拧紧螺母即可,不必担

心螺钉会跟转。

1194357-T01-L12Kohler Co.

三通

进水软管

角阀

软管

6.连接供水系统

重要!产品损坏的危险。小心对正进水管与座便盖的螺纹,不要破坏螺纹

或过于拧紧接头。为了牢固的拧紧接头,用手拧紧后用工具再拧紧1/4圈。

重要!产品损坏的危险。小心不要刮伤产品表面。

直接将三通与座便器进水管口相连。

注意:对新安装的管路系统,在将进水软管连接至三通以前,须直接

排水数秒,以清除管道内沙石、污垢等。

用提供的软管连接三通和座便盖。

注意!必须使用随器具附带的新软管组件,旧软管组件不能重复使用。

把三通与供水系统相连(角阀需客户自行购买)。

打开供水系统。

注意!一定要先彻底冲洗供水管以清除管道中的杂质,使用水

源为饮用自来水,切勿使用工业用水、废水、污水以及海水。

检查所有连接是否有漏水,如果需要可做调整。

Kohler Co.131194357-T01-L

1

7.安装检查

确认进水阀是否已打开。

用塑料布包裹在座圈上,防止测试时水喷出。

把电源线插上电源插座,座便盖发出短蜂鸣1次,喷管伸缩1次,侧键

盘上背光灯点亮,夜灯闪烁,直至初始化结束。

在软管和电源线间扣上线夹。

座圈设计为有落座感应启动工作。为了激活座圈达到测试的目的,首

先面对座便器,然后把手或者一块湿布放在座圈右边离前端大约1/3处

(感应区域)。

继续参考用户手册中的“使用方法”部分来测试产品的不同功能。

1194357-T01-L14Kohler Co.


更多推荐